Supporting Utilities
Description
Facility security mechanisms exist to protect power equipment and power cabling for the system from damage and destruction.
Possible Solutions & Considerations
Micro-Small Business (<10 staff) / BLS Firm Size Classes 1-2
∙ Power strips/UPS kept in secured area; cords protected from damage
Small Business (10-49 staff) / BLS Firm Size Classes 3-4
∙ UPS and power equipment in locked server room ∙ Power cabling protected from accidental damage
Medium Business (50-249 staff) / BLS Firm Size Classes 5-6
∙ Power distribution units and UPS in access-controlled rooms ∙ Protected power cabling pathways ∙ Facilities maintenance program
Large Business (250-999 staff) / BLS Firm Size Classes 7-8
∙ Data center power infrastructure (UPS, PDUs, generators) in restricted areas ∙ Protected and documented power cabling ∙ Regular inspection and maintenance
Enterprise (> 1,000 staff) / BLS Firm Size Class 9
∙ Enterprise power infrastructure protection (secured electrical rooms, redundant feeds, protected cabling) ∙ DCIM monitoring of power equipment ∙ Formal maintenance and inspection program
SCR-CMM
Level 0 Not Performed
Practices are non-existent, based on the inability to demonstrate an implemented and operational capability. A reasonable person would conclude the control is not being performed.
Level 1 Performed Informally
Physical & Environmental Security (PES) domain capabilities are ad hoc and inconsistent. Capability criteria associated with this control may include: ▪ Policies, standards & procedures associated with PES domain capabilities provide limited coverage due to the depth and breadth of the existing documentation. ▪ Physical security-related activities are decentralized (e.g., a localized/regionalized function) and uses non-standardized methods to implement secure, resilient and compliant practices. ▪ Physical security controls are primarily administrative in nature (e.g., policies & standards), focusing on protecting High Value Assets (HVAs). ▪ IT and/or cybersecurity personnel implement appropriate physical security practices to protect the confidentiality, integrity, availability and safety of the organization's technology assets and data.
Level 2 Planned Tracked
Physical & Environmental Security (PES) capabilities are requirements-driven, but are not standardized across the entity (e.g., local/regional level consistency). Capability criteria associated with this control reasonably expect the following criteria to exist: ▪ Policies and standards associated with PES domain capabilities are formally documented and centrally-managed by the entity. ▪ Standardized Operating Procedures (SOP) associated with PES domain capabilities are documented and maintained by process owners. ▪ IT and/or cybersecurity personnel work with business stakeholders and process owners to appropriately scope and reasonably implement cybersecurity and data protection controls associated with PES domain capabilities to address applicable statutory, regulatory and/or contractual requirements for Technology Assets, Applications, Services and/or Data (TAASD). ▪ Physical security / facilities management-related controls are primarily administrative and preventative in nature (e.g., policies, standards and procedures & guidelines). ▪ Physical security / facilities management may be a defined function (e.g., team or department) or assigned as an additional duty to existing IT and/or cybersecurity personnel. ▪ Physical security controls and technologies primarily focus on protecting High Value Assets (HVAs), including environments where sensitive/regulated data is stored, transmitted and processed.
Level 3 Well Defined
Physical & Environmental Security (PES) capabilities are standardized across the entity for applicability to People, Processes, Technologies, Data and/or Facilities (PPTDF) to ensure consistency for Technology Assets, Applications, Services and/or Data (TAASD). Capability criteria associated with this control reasonably expect the following criteria to exist: ▪ Policies and standards associated with PES domain capabilities are formally documented and centrally-managed by the entity's Governance, Risk & Compliance (GRC) team, or similar function. ▪ Standardized Operating Procedures (SOP) associated with PES domain capabilities are well-documented and kept current by process owners. ▪ A facilities management team, or similar function, is appropriately staffed and supported to implement and maintain NET domain capabilities. ▪ Technology is leveraged to enhance the efficiency and accuracy of physical and environmental security operations (e.g., facility management solution, visitor log management automation and proximity badge access). ▪ The entity's Governance, Risk & Compliance (GRC) team, or similar function, works with business stakeholders and process owners to appropriately scope and reasonably implement cybersecurity and data protection controls associated with PES domain capabilities to address Minimum Compliance Requirements (MCR) (e.g., applicable statutory, regulatory and/or contractual requirements) and Discretionary Security Requirements (DSR) (e.g., entity-required controls). ▪ An implemented and operational physical security capability exists to protect power equipment and power cabling for the system from damage and destruction.
Level 4 Quantitatively Controlled
Physical & Environmental Security (PES) capabilities, in addition to being standardized across the entity and centrally managed to ensure consistency across Technology Assets, Applications, Services and/or Data (TAASD), efforts are metrics driven to provide sufficient insight for decision makers to predict optimal performance, ensure continued operations and/or identify areas for improvement. Capability criteria associated with this control reasonably expect the following criteria to exist: ▪ Applicable SCR-CMM Level 3 (Well Defined) capabilities are implemented and operational. ▪ Metrics reporting includes quantitative analysis of Key Performance Indicators (KPIs). ▪ Metrics reporting includes quantitative analysis of Key Risk Indicators (KRIs). ▪ Scope of metrics, KPIs and KRIs covers organization-wide cybersecurity and data protection controls, including functions performed by third-parties. ▪ Organizational leadership maintains a formal process to objectively review and respond to metrics, KPIs and KRIs (e.g., monthly or quarterly review). ▪ Based on metrics analysis, process improvement recommendations are submitted for review and are handled in accordance with change control processes. ▪ Business and technical stakeholders are involved in reviewing and approving proposed changes to evolve capabilities.
Level 5 Continuously Improving
Utilize SCR-CMM Level 3 or Level 4 (if available) criteria definitions: ▪ There are no defined Level 5 criteria, since it is reasonable to assume a continuously-improving process is not necessary to operationalize this control. ▪ Level 5 capabilities should be considered “world-class” where the control builds on Level 4 capabilities, but are continuously improving through Artificial Intelligence (AI) and/or Machine Learning (ML) technologies. ▪ While it may be possible to develop responsive capabilities for this control through the use of AI and/or ML technologies, the criteria would be organization-specific to define.
1. Přehled
| Název |
Standard |
|
Automatic Voltage Controls
|
Description
Facility security mechanisms exist to utilize automatic voltage controls for critical system components.
Possible Solutions & Considerations
Micro-Small Business (<10 staff) / BLS Firm Size Classes 1-2
∙ UPS with automatic voltage regulation for critical equipment
Small Business (10-49 staff) / BLS Firm Size Classes 3-4
∙ Line-interactive or online UPS with voltage regulation for servers and network gear
Medium Business (50-249 staff) / BLS Firm Size Classes 5-6
∙ Online (double-conversion) UPS for critical systems ∙ Surge protection at panel level
Large Business (250-999 staff) / BLS Firm Size Classes 7-8
∙ Data center UPS with automatic voltage regulation and power conditioning ∙ Facility-level surge protection
Enterprise (> 1,000 staff) / BLS Firm Size Class 9
∙ Enterprise power conditioning and UPS infrastructure with N+1 redundancy ∙ Facility-wide automatic voltage regulation and surge protection ∙ DCIM power quality monitoring
SCR-CMM
Level 0 Not Performed
Practices are non-existent, based on the inability to demonstrate an implemented and operational capability. A reasonable person would conclude the control is not being performed.
Level 1 Performed Informally
Physical & Environmental Security (PES) domain capabilities are ad hoc and inconsistent. Capability criteria associated with this control may include: ▪ Policies, standards & procedures associated with PES domain capabilities provide limited coverage due to the depth and breadth of the existing documentation. ▪ Physical security-related activities are decentralized (e.g., a localized/regionalized function) and uses non-standardized methods to implement secure, resilient and compliant practices. ▪ Physical security controls are primarily administrative in nature (e.g., policies & standards), focusing on protecting High Value Assets (HVAs). ▪ IT and/or cybersecurity personnel implement appropriate physical security practices to protect the confidentiality, integrity, availability and safety of the organization's technology assets and data.
Level 2 Planned Tracked
Physical & Environmental Security (PES) capabilities are requirements-driven, but are not standardized across the entity (e.g., local/regional level consistency). Capability criteria associated with this control reasonably expect the following criteria to exist: ▪ Policies and standards associated with PES domain capabilities are formally documented and centrally-managed by the entity. ▪ Standardized Operating Procedures (SOP) associated with PES domain capabilities are documented and maintained by process owners. ▪ IT and/or cybersecurity personnel work with business stakeholders and process owners to appropriately scope and reasonably implement cybersecurity and data protection controls associated with PES domain capabilities to address applicable statutory, regulatory and/or contractual requirements for Technology Assets, Applications, Services and/or Data (TAASD). ▪ Physical security / facilities management-related controls are primarily administrative and preventative in nature (e.g., policies, standards and procedures & guidelines). ▪ Physical security / facilities management may be a defined function (e.g., team or department) or assigned as an additional duty to existing IT and/or cybersecurity personnel. ▪ Physical security controls and technologies primarily focus on protecting High Value Assets (HVAs), including environments where sensitive/regulated data is stored, transmitted and processed.
Level 3 Well Defined
Physical & Environmental Security (PES) capabilities are standardized across the entity for applicability to People, Processes, Technologies, Data and/or Facilities (PPTDF) to ensure consistency for Technology Assets, Applications, Services and/or Data (TAASD). Capability criteria associated with this control reasonably expect the following criteria to exist: ▪ Policies and standards associated with PES domain capabilities are formally documented and centrally-managed by the entity's Governance, Risk & Compliance (GRC) team, or similar function. ▪ Standardized Operating Procedures (SOP) associated with PES domain capabilities are well-documented and kept current by process owners. ▪ A facilities management team, or similar function, is appropriately staffed and supported to implement and maintain NET domain capabilities. ▪ Technology is leveraged to enhance the efficiency and accuracy of physical and environmental security operations (e.g., facility management solution, visitor log management automation and proximity badge access). ▪ The entity's Governance, Risk & Compliance (GRC) team, or similar function, works with business stakeholders and process owners to appropriately scope and reasonably implement cybersecurity and data protection controls associated with PES domain capabilities to address Minimum Compliance Requirements (MCR) (e.g., applicable statutory, regulatory and/or contractual requirements) and Discretionary Security Requirements (DSR) (e.g., entity-required controls). ▪ An implemented and operational physical security capability exists to utilize automatic voltage controls for critical system components.
Level 4 Quantitatively Controlled
Physical & Environmental Security (PES) capabilities, in addition to being standardized across the entity and centrally managed to ensure consistency across Technology Assets, Applications, Services and/or Data (TAASD), efforts are metrics driven to provide sufficient insight for decision makers to predict optimal performance, ensure continued operations and/or identify areas for improvement. Capability criteria associated with this control reasonably expect the following criteria to exist: ▪ Applicable SCR-CMM Level 3 (Well Defined) capabilities are implemented and operational. ▪ Metrics reporting includes quantitative analysis of Key Performance Indicators (KPIs). ▪ Metrics reporting includes quantitative analysis of Key Risk Indicators (KRIs). ▪ Scope of metrics, KPIs and KRIs covers organization-wide cybersecurity and data protection controls, including functions performed by third-parties. ▪ Organizational leadership maintains a formal process to objectively review and respond to metrics, KPIs and KRIs (e.g., monthly or quarterly review). ▪ Based on metrics analysis, process improvement recommendations are submitted for review and are handled in accordance with change control processes. ▪ Business and technical stakeholders are involved in reviewing and approving proposed changes to evolve capabilities.
Level 5 Continuously Improving
Utilize SCR-CMM Level 3 or Level 4 (if available) criteria definitions: ▪ There are no defined Level 5 criteria, since it is reasonable to assume a continuously-improving process is not necessary to operationalize this control. ▪ Level 5 capabilities should be considered “world-class” where the control builds on Level 4 capabilities, but are continuously improving through Artificial Intelligence (AI) and/or Machine Learning (ML) technologies. ▪ While it may be possible to develop responsive capabilities for this control through the use of AI and/or ML technologies, the criteria would be organization-specific to define.
|
1.1 Odkazy
1.2 Identifikované požadavky
1.3 Související regulace
2. Identifikované požadavky
Požadavky
| Zdroj |
Požadavek |
3. Související regulace
Propojené úkoly
- Secure Controls Framework -
"The SCF is the Common Controls Framework™ (CCF), the world's most comprehensive cybersecurity and data privacy metaframework - it is also free to use. The entire concept is building secure, compliant and resilient capabilities in the most efficient and cost-effective manner possible.
The SCF is more than just a unified control catalog, since its included content creates a playbook for Governance, Risk & Compliance (GRC) capabilities. Used globally by organizations of every size, the SCF is a robust and scalable solution for security, compliance and resilience controls. As a comprehensive security framework, the SCF maps 1,400+ controls across 200+ laws, regulations, and industry frameworks so you can implement once and comply everywhere.
Like it or not, cybersecurity is a protracted war on an asymmetric battlefield, where the threats are everywhere and as defenders we have to make the effort to work together to help improve cybersecurity and data privacy practices, since we all suffer when massive data breaches occur or when cyber attacks have physical impacts. Hackers share information on attack methods with other hackers, so why shouldn’t the good guys share information on how to best protect an organization? We decided to take action and make a difference, since we feel it is too important to wait for someone else to fix the problems that exist.
The SCF is made up of volunteers, mainly specialists within the cybersecurity profession, who focus on GRC and the cybersecurity side of data privacy. These are auditors, engineers, architects, incident responders, consultants and other specialists who live and breathe these topics on a daily basis. The end product is "expert-derived content" that makes up the SCF." https://securecontrolsframework.com/
Terms & Conditions
The SCF End User License Agreement (EULA) governs the use of the Secure Controls Framework® (SCF) under the Creative Commons Attribution-No Derivatives 4.0 International Public License.
|