+SYS.1.7.A16 Monitoring of z/OS Systems (S)
|
SYS.1.7.A16 Monitoring of z/OS Systems (S)
During operation, the z/OS system SHOULD be monitored for important messages, events, and compliance with thresholds. In particular, error messages on the HMC console, WTOR and important WTO messages (write to operator/with reply), system tasks, security breaches, capacity limits, and system utilisation SHOULD be considered. At minimum, the MCS console, the system management facility, the SYSLOG, and the relevant log data of applications SHOULD also be used for monitoring. It SHOULD be ensured that all important messages are recognised promptly and responded to in an appropriate manner when required. System messages SHOULD be filtered in such a way that only those messages that are actually important are displayed.
1. Übersicht
1.1 Referenzen
1.2 Identifizierte Anforderungen
1.3 Zugehörige Regulierungen
2. Identifizierte Anforderungen
Anforderungen
| Quelle |
Anforderung |
3. Zugehörige Regulierungen
Regulierungen
| Quelle |
Regulierung |
Verknüpfte Vorgänge
|