+Article 12 2.

Article 12 2.

By 18 August 2024, the technical documentation referred to in Annex VIII shall:

(a) 

demonstrate that the stationary battery energy storage systems are compliant with paragraph 1 and include evidence that they have been successfully tested for the safety parameters set out in Annex V, for which state-of-the-art testing methodologies shall be used. The safety parameters shall only apply in so far as a corresponding hazard exists for the stationary battery energy storage system in question when it is used under the conditions envisaged by the manufacturer;

(b) 

include an assessment of possible safety hazards of the stationary battery energy storage system that are not addressed in Annex V;

(c) 

include evidence that the hazards referred to in point (b) have been successfully mitigated and tested; state-of-the-art testing methodologies shall be used for such testing;

(d) 

include mitigation instructions in case the identified hazards could occur, for example a fire or explosion.

The technical documentation shall be reviewed if a battery is prepared for re-use, prepared for repurposing, remanufactured or repurposed.

1. Panoramica

,
Titolo Regolamentazione

1.1 Riferimenti

1.2 Requisiti identificati

1.3 Standard correlati

2. Requisiti identificati

Requisiti
Fonte Requisito

3. Standard correlati

Standard
Fonte Requisito