Assessment Objective
Determine if:
- PE-19 the system is protected from information leakage due to electromagnetic signal emanations.
Assessment Methods
Examine
- Physical and environmental protection policy
- procedures addressing information leakage due to electromagnetic signal emanations
- mechanisms protecting the system against electronic signal emanations
- facility housing the system
- records from electromagnetic signal emanation tests
- system security plan
- other relevant documents or records
Interview
- Organizational personnel with responsibilities for system environmental controls
- organizational personnel with information security responsibilities
Test
- Mechanisms supporting and/or implementing protection from information leakage due to electromagnetic signal emanations