|
+Deficiency Tracking Automation |
Deficiency Tracking AutomationDescriptionAutomated mechanisms exist to help ensure tracked deficiencies are:(1) Accurate; (2) Up-to-date; and (3) Readily-available. Possible Solutions & ConsiderationsMicro-Small Business (<10 staff) / BLS Firm Size Classes 1-2∙ Plan of Action and Milestones (POA&M) spreadsheet kept currentSmall Business (10-49 staff) / BLS Firm Size Classes 3-4∙ POA&M tracked in ticketing/spreadsheet with owners and datesMedium Business (50-249 staff) / BLS Firm Size Classes 5-6∙ GRC solution (e.g., SCFConnect, Cyturus, SureCloud, SimpleRisk, Ignyte, ZenGRC, Galvanize, MetricStream, Archer, etc.) for POA&M tracking∙ Automated reminders and status updates Large Business (250-999 staff) / BLS Firm Size Classes 7-8∙ GRC platform with automated deficiency tracking and integration with vulnerability/ticketing systems∙ Real-time POA&M dashboards Enterprise (> 1,000 staff) / BLS Firm Size Class 9∙ Enterprise GRC platform with automated POA&M lifecycle management, integrations and executive dashboards (e.g., Archer, MetricStream, ServiceNow IRM, Cyturus)SCR-CMMLevel 0 Not PerformedPractices are non-existent, based on the inability to demonstrate an implemented and operational capability. A reasonable person would conclude the control is not being performed.Level 1 Performed InformallyInformation Assurance (IAO) domain capabilities are ad hoc and inconsistent. Capability criteria associated with this control may include:▪ Policies, standards & procedures associated with IAO domain capabilities provide limited coverage due to the depth and breadth of the existing documentation. ▪ Pre-production security testing-related activities are decentralized (e.g., a localized/regionalized function) and uses non-standardized methods to implement secure, resilient and compliant practices. ▪ IT and/or cybersecurity personnel implement and maintain an informal process to conduct limited control testing of High Value Assets (HVAs) to meet specific statutory, regulatory and/or contractual requirements for pre-production cybersecurity and data protection control testing. Level 2 Planned TrackedSCR-CMM Level 2 criteria definitions are not available for this control:▪ A reasonable person would conclude a well-defined and standardized process is required. ▪ At this level of maturity, the “requirements-driven” nature of performing the control is focused on a localized and/or regionalized implementation, not uniform and consistent across the organization. ▪ Requirements are narrowly scoped for applicability and are primarily derived from compliance obligations (e.g., laws, regulations and contracts). Level 3 Well DefinedInformation Assurance (IAO) capabilities are standardized across the entity for applicability to People, Processes, Technologies, Data and/or Facilities (PPTDF) to ensure consistency for Technology Assets, Applications, Services and/or Data (TAASD). Capability criteria associated with this control reasonably expect the following criteria to exist:▪ Policies and standards associated with IAO domain capabilities are formally documented and centrally-managed by the entity's Governance, Risk & Compliance (GRC) team, or similar function. ▪ Standardized Operating Procedures (SOP) associated with IAO domain capabilities are well-documented and kept current by process owners. ▪ An information assurance team, or similar function, is appropriately staffed and supported to implement and maintain IAO domain capabilities. ▪ Technology is leveraged to enhance the efficiency and accuracy of information assurance operations (e.g., assessment scheduling software and risk assessment software). ▪ The entity's Governance, Risk & Compliance (GRC) team, or similar function, works with business stakeholders and process owners to appropriately scope and reasonably implement cybersecurity and data protection controls associated with IAO domain capabilities to address Minimum Compliance Requirements (MCR) (e.g., applicable statutory, regulatory and/or contractual requirements) and Discretionary Security Requirements (DSR) (e.g., entity-required controls). ▪ An implemented and operational capability exists to automate deficiency tracking to ensure records are: (1) Accurate; (2) Up-to-date; and (3) Readily-available. Level 4 Quantitatively ControlledUtilize SCR-CMM Level 3 criteria definitions:▪ There are no defined Level 4 criteria, since it is reasonable to assume a quantitatively-controlled process is not necessary to operationalize this control. ▪ While it may be possible to develop “metrics-driven” capabilities for this control, the criteria would be organization-specific to define. Level 5 Continuously ImprovingUtilize SCR-CMM Level 3 or Level 4 (if available) criteria definitions:▪ There are no defined Level 5 criteria, since it is reasonable to assume a continuously-improving process is not necessary to operationalize this control. ▪ Level 5 capabilities should be considered “world-class” where the control builds on Level 4 capabilities, but are continuously improving through Artificial Intelligence (AI) and/or Machine Learning (ML) technologies. ▪ While it may be possible to develop responsive capabilities for this control through the use of AI and/or ML technologies, the criteria would be organization-specific to define. 1. Przegląd
1.1 Odwołania1.2 Zidentyfikowane wymagania1.3 Powiązane regulacje2. Zidentyfikowane wymagania
3. Powiązane regulacje
Powiązane zgłoszenia
|