+03.10 Physical Protection
---+03.10.01 Physical Access Authorizations
---+03.10.02 Monitoring Physical Access
---+SP_800_171_03.10.03 03.10.03
---+SP_800_171_03.10.04 03.10.04
---+SP_800_171_03.10.05 03.10.05
---+03.10.06 Alternate Work Site
---+03.10.07 Physical Access Control
---+03.10.08 Access Control for Transmission
|
03.10 Physical Protection
Physical Protection
1. Visão geral
| Título |
Norma |
|
03.10.01 Physical Access Authorizations
|
Statementa. Develop, approve, and maintain a list of individuals with authorized access to the facility where the system resides. b. Issue authorization credentials for facility access. c. Review the facility access list {{ insert: param, A.03.10.01.ODP.01 }}. d. Remove individuals from the facility access list when access is no longer required.
GuidanceA facility can include one or more physical locations containing systems or system components that process, store, or transmit CUI. Physical access authorizations apply to employees and visitors. Individuals with permanent physical access authorization credentials are not considered visitors. Authorization credentials include identification badges, identification cards, and smart cards. Organizations determine the strength of the authorization credentials consistent with applicable laws, Executive Orders, directives, regulations, policies, standards, and guidelines. Physical access authorizations may not be necessary to access certain areas within facilities that are designated as publicly accessible. Assessment objectivea list of individuals with authorized access to the facility where the system resides is developed. Assessment objectivea list of individuals with authorized access to the facility where the system resides is approved. Assessment objectivea list of individuals with authorized access to the facility where the system resides is maintained. Assessment objectivethe facility access list is reviewed {{ insert: param, A.03.10.01.ODP.01 }}. Assessment objectiveindividuals from the facility access list are removed when access is no longer required. Assessment objectiveauthorization credentials for facility access are issued. Assessment methodAssessment methodAssessment method
|
|
03.10.02 Monitoring Physical Access
|
Statementa. Monitor physical access to the facility where the system resides to detect and respond to physical security incidents. b. Review physical access logs {{ insert: param, A.03.10.02.ODP.01 }} and upon occurrence of {{ insert: param, A.03.10.02.ODP.02 }}.
GuidanceA facility can include one or more physical locations containing systems or system components that process, store, or transmit CUI. Physical access monitoring includes publicly accessible areas within organizational facilities. Examples of physical access monitoring include guards, video surveillance equipment (i.e., cameras), and sensor devices. Reviewing physical access logs can help to identify suspicious activities, anomalous events, or potential threats. The reviews can be supported by audit logging controls if the access logs are part of an automated system. Incident response capabilities include investigations of physical security incidents and responses to those incidents. Incidents include security violations or suspicious physical access activities, such as access outside of normal work hours, repeated access to areas not normally accessed, access for unusual lengths of time, and out-of-sequence access. Assessment objectivephysical access to the facility where the system resides is monitored to detect physical security incidents. Assessment objectivephysical security incidents are responded to. Assessment objectivephysical access logs are reviewed {{ insert: param, A.03.10.02.ODP.01 }} . Assessment objectivephysical access logs are reviewed upon occurrence of {{ insert: param, A.03.10.02.ODP.02 }}. Assessment methodAssessment methodAssessment method
|
|
SP_800_171_03.10.03 03.10.03
|
|
|
SP_800_171_03.10.04 03.10.04
|
|
|
SP_800_171_03.10.05 03.10.05
|
|
|
03.10.06 Alternate Work Site
|
Statementa. Determine alternate work sites allowed for use by employees. b. Employ the following security requirements at alternate work sites: {{ insert: param, A.03.10.06.ODP.01 }}.
GuidanceAlternate work sites include the private residences of employees or other facilities designated by the organization. Alternate work sites can provide readily available alternate locations during contingency operations. Organizations can define different security requirements for specific alternate work sites or types of sites, depending on the work-related activities conducted at the sites. Assessing the effectiveness of the requirements and providing a means to communicate incidents at alternate work sites supports the contingency planning activities of organizations. Assessment objectivealternate work sites allowed for use by employees are determined. Assessment objectivethe following security requirements are employed at alternate work sites: {{ insert: param, A.03.10.06.ODP.01 }}. Assessment methodAssessment methodAssessment method
|
|
03.10.07 Physical Access Control
|
Statementa. Enforce physical access authorizations at entry and exit points to the facility where the system resides by: 01. Verifying individual physical access authorizations before granting access to the facility and 02. Controlling ingress and egress with physical access control systems, devices, or guards.
b. Maintain physical access audit logs for entry or exit points. c. Escort visitors, and control visitor activity. d. Secure keys, combinations, and other physical access devices. e. Control physical access to output devices to prevent unauthorized individuals from obtaining access to CUI.
GuidanceThis requirement addresses physical locations containing systems or system components that process, store, or transmit CUI. Organizations determine the types of guards needed, including professional security staff or administrative staff. Physical access devices include keys, locks, combinations, biometric readers, and card readers. Physical access control systems comply with applicable laws, Executive Orders, directives, policies, regulations, standards, and guidelines. Organizations have flexibility in the types of audit logs employed. Audit logs can be procedural, automated, or some combination thereof. Physical access points can include exterior access points, interior access points to systems that require supplemental access controls, or both. Physical access control applies to employees and visitors. Individuals with permanent physical access authorizations are not considered visitors. Controlling physical access to output devices includes placing output devices in locked rooms or other secured areas with keypad or card reader access controls and only allowing access to authorized individuals, placing output devices in locations that can be monitored by personnel, installing monitor or screen filters, and using headphones. Examples of output devices include monitors, printers, scanners, facsimile machines, audio devices, and copiers. Assessment objectivephysical access authorizations are enforced at entry and exit points to the facility where the system resides by verifying individual physical access authorizations before granting access. Assessment objectivephysical access authorizations are enforced at entry and exit points to the facility where the system resides by controlling ingress and egress with physical access control systems, devices, or guards. Assessment objectivephysical access audit logs for entry or exit points are maintained. Assessment objectivevisitors are escorted. Assessment objectivevisitor activity is controlled. Assessment objectivephysical access to output devices is controlled to prevent unauthorized individuals from obtaining access to CUI. Assessment objectivekeys, combinations, and other physical access devices are secured. Assessment methodAssessment methodAssessment method
|
|
03.10.08 Access Control for Transmission
|
StatementControl physical access to system distribution and transmission lines within organizational facilities. GuidanceSafeguarding measures applied to system distribution and transmission lines prevent accidental damage, disruption, and physical tampering. Such measures may also be necessary to prevent eavesdropping or the modification of unencrypted transmissions. Safeguarding measures used to control physical access to system distribution and transmission lines include disconnected or locked spare jacks, locked wiring closets, cabling protection with conduit or cable trays, and wiretapping sensors. Assessment objectivephysical access to system distribution and transmission lines within organizational facilities is controlled. Assessment methodAssessment methodAssessment method
|
1.1 Referências
1.2 Requisitos identificados
1.3 Regulamentos relacionados
2. Requisitos identificados
Requisitos
| Fonte |
Requisito |
3. Regulamentos relacionados
Regulamentos
| Fonte |
Regulamentação |
|