+NET.1.1.A29 Implementing Network Connections for High Availability (H)

NET.1.1.A29 Implementing Network Connections for High Availability (H)

The network connections (such as the Internet connection and WAN connections) SHOULD be designed with full redundancy. Depending on the availability requirements at hand, redundant connections to one or more providers SHOULD be implemented with different technology and performance. Redundant routes SHOULD also be implemented as needed both within and outside of an organisation's purview. To this end, possible single points of failure (SPoF) and disruptive environmental conditions SHOULD be considered.