+Article 50 4.

Article 50 4.

Waste incineration plants and waste co-incineration plants shall operate an automatic system to prevent waste feed in the following situations:

(a) 

at start-up, until the temperature set out in paragraph 2 of this Article or the temperature specified in accordance with Article 51(1) has been reached;

(b) 

whenever the temperature set out in paragraph 2 of this Article or the temperature specified in accordance with Article 51(1) is not maintained;

(c) 

whenever the continuous measurements show that any emission limit value is exceeded due to disturbances or failures of the waste gas cleaning devices.