+ANNEX V Template for energy performance certificates |
ANNEX V Template for energy performance certificates
ANNEX V Template for energy performance certificates (referred to in Article 19) 1. On its front page, the energy performance certificate shall display at least the following elements:
(a)
the energy performance class;
(b)
the calculated annual primary energy use in kWh/(m2.y);
(c)
the calculated annual final energy use in kWh/(m2.y);
(d)
renewable energy produced on-site in % of energy use;
(e)
operational greenhouse gas emissions (kgCO2/(m2.y)), and the value of the life-cycle GWP, if available. The energy performance certificate shall also display the following elements:
(a)
the calculated annual primary and final energy consumption in kWh or MWh;
(b)
renewable energy production in kWh or MWh; main energy carrier and type of renewable energy source;
(c)
the calculated energy needs in kWh/(m2.y);
(d)
a yes/no indication whether the building has a capacity to react to external signals and adjust the energy consumption;
(e)
a yes/no indication whether the heat distribution system inside the building is capable to work at low or more efficient temperature levels, where applicable;
(f)
the contact information of the relevant one-stop shop for renovation advice. 2. In addition, the energy performance certificate may include the following indicators:
(a)
energy use, peak load, size of generator or system, main energy carrier and main type of element for each of the uses: heating, cooling, domestic hot water, ventilation and in-built lighting;
(b)
the greenhouse gas emission class (if applicable);
(c)
information on carbon removals associated to the temporary storage of carbon in or on buildings;
(d)
a yes/no indication whether a renovation passport is available for the building;
(e)
the average U-value for the opaque elements of the building envelope;
(f)
the average U-value for the transparent elements of the building envelope;
(g)
type of most common transparent element (e.g. double-glazed window);
(h)
results of the analysis on overheating risk (if available);
(i)
the presence of fixed sensors that monitor the indoor environmental quality;
(j)
the presence of fixed controls that respond to the levels of indoor environmental quality;
(k)
number and type of recharging points for electric vehicles;
(l)
presence, type and size of energy storage systems;
(m)
expected remaining lifespan of the heating or air-conditioning systems and appliances, where applicable;
(n)
feasibility of adapting the heating system to operate at more efficient temperature settings;
(o)
feasibility of adapting the domestic hot-water system to operate at more efficient temperature settings;
(p)
feasibility of adapting the air-conditioning system to operate at more efficient temperature settings;
(q)
metered energy consumption;
(r)
whether there is a connection to a district heating and cooling network, and, if available, information about a potential connection to an efficient district heating and cooling system;
(s)
local primary energy factors and related carbon emission factors of the connected local district heating and cooling network;
(t)
operational fine particulate matter (PM 2,5 ) emissions. The energy performance certificate may include the following links with other initiatives if these apply in the relevant Member State:
(a)
a yes/no indication whether a smart readiness assessment has been carried out for the building;
(b)
where available, the value of the smart readiness assessment;
(c)
a yes/no indication whether a Digital Building Logbook is available for the building. Persons with disabilities shall have equal access to the information in energy performance certificates. 1. Przegląd
1.1 Odwołania1.2 Zidentyfikowane wymagania1.3 Powiązane normy2. Zidentyfikowane wymagania
3. Powiązane normy
|