+Role-Based Physical Access
---+Dual Authorization for Physical Access
|
Role-Based Physical Access
Description
Physical access control mechanisms exist to authorize physical access to facilities based on the position or role of the individual.
Possible Solutions & Considerations
Micro-Small Business (<10 staff) / BLS Firm Size Classes 1-2
∙ Key or badge issuance based on job role ∙ Server closet access limited to owner/IT contact
Small Business (10-49 staff) / BLS Firm Size Classes 3-4
∙ Role-based badge access groups in door access system ∙ Documented access matrix by role
Medium Business (50-249 staff) / BLS Firm Size Classes 5-6
∙ Physical access control system with role-based access levels (e.g., Brivo, Verkada, Kisi) ∙ Access matrix reviewed with HR role changes
Large Business (250-999 staff) / BLS Firm Size Classes 7-8
∙ Enterprise physical access control system with role-based zones (e.g., Lenel, Genetec, Honeywell) ∙ HR-driven role provisioning for physical access ∙ Periodic access recertification by area owner
Enterprise (> 1,000 staff) / BLS Firm Size Class 9
∙ Enterprise PACS integrated with identity governance for role-based physical access ∙ Automated provisioning/deprovisioning from HR events ∙ Quarterly access recertification by facility zone
SCR-CMM
Level 0 Not Performed
Practices are non-existent, based on the inability to demonstrate an implemented and operational capability. A reasonable person would conclude the control is not being performed.
Level 1 Performed Informally
SCR-CMM Level 1 criteria definitions are not available for this control: ▪ A reasonable person would conclude this control requires a structured process. ▪ At this level of maturity, the "ad hoc" nature of performing a capability informally would indicate the intent of the control is not met due to a lack of consistency and formality.
Level 2 Planned Tracked
Physical & Environmental Security (PES) capabilities are requirements-driven, but are not standardized across the entity (e.g., local/regional level consistency). Capability criteria associated with this control reasonably expect the following criteria to exist: ▪ Policies and standards associated with PES domain capabilities are formally documented and centrally-managed by the entity. ▪ Standardized Operating Procedures (SOP) associated with PES domain capabilities are documented and maintained by process owners. ▪ IT and/or cybersecurity personnel work with business stakeholders and process owners to appropriately scope and reasonably implement cybersecurity and data protection controls associated with PES domain capabilities to address applicable statutory, regulatory and/or contractual requirements for Technology Assets, Applications, Services and/or Data (TAASD). ▪ Physical security / facilities management-related controls are primarily administrative and preventative in nature (e.g., policies, standards and procedures & guidelines). ▪ Physical security / facilities management may be a defined function (e.g., team or department) or assigned as an additional duty to existing IT and/or cybersecurity personnel. ▪ Physical security controls and technologies primarily focus on protecting High Value Assets (HVAs), including environments where sensitive/regulated data is stored, transmitted and processed. ▪ The Human Resources (HR) department maintains a current list of personnel with authorized access to organizational facilities and facilitates the implementation of physical access management controls.
Level 3 Well Defined
Physical & Environmental Security (PES) capabilities are standardized across the entity for applicability to People, Processes, Technologies, Data and/or Facilities (PPTDF) to ensure consistency for Technology Assets, Applications, Services and/or Data (TAASD). Capability criteria associated with this control reasonably expect the following criteria to exist: ▪ Policies and standards associated with PES domain capabilities are formally documented and centrally-managed by the entity's Governance, Risk & Compliance (GRC) team, or similar function. ▪ Standardized Operating Procedures (SOP) associated with PES domain capabilities are well-documented and kept current by process owners. ▪ A facilities management team, or similar function, is appropriately staffed and supported to implement and maintain NET domain capabilities. ▪ Technology is leveraged to enhance the efficiency and accuracy of physical and environmental security operations (e.g., facility management solution, visitor log management automation and proximity badge access). ▪ The entity's Governance, Risk & Compliance (GRC) team, or similar function, works with business stakeholders and process owners to appropriately scope and reasonably implement cybersecurity and data protection controls associated with PES domain capabilities to address Minimum Compliance Requirements (MCR) (e.g., applicable statutory, regulatory and/or contractual requirements) and Discretionary Security Requirements (DSR) (e.g., entity-required controls). ▪ An implemented and operational physical security capability exists to authorize physical access to facilities based on the position or role of the individual.
Level 4 Quantitatively Controlled
Physical & Environmental Security (PES) capabilities, in addition to being standardized across the entity and centrally managed to ensure consistency across Technology Assets, Applications, Services and/or Data (TAASD), efforts are metrics driven to provide sufficient insight for decision makers to predict optimal performance, ensure continued operations and/or identify areas for improvement. Capability criteria associated with this control reasonably expect the following criteria to exist: ▪ Applicable SCR-CMM Level 3 (Well Defined) capabilities are implemented and operational. ▪ Metrics reporting includes quantitative analysis of Key Performance Indicators (KPIs). ▪ Metrics reporting includes quantitative analysis of Key Risk Indicators (KRIs). ▪ Scope of metrics, KPIs and KRIs covers organization-wide cybersecurity and data protection controls, including functions performed by third-parties. ▪ Organizational leadership maintains a formal process to objectively review and respond to metrics, KPIs and KRIs (e.g., monthly or quarterly review). ▪ Based on metrics analysis, process improvement recommendations are submitted for review and are handled in accordance with change control processes. ▪ Business and technical stakeholders are involved in reviewing and approving proposed changes to evolve capabilities.
Level 5 Continuously Improving
Physical & Environmental Security (PES) capabilities, in addition to being standardized across the entity and centrally managed to ensure consistency across Technology Assets, Applications, Services and/or Data (TAASD), efforts are metrics driven to provide sufficient insight for decision makers to predict optimal performance, ensure continued operations and/or identify areas for improvement. Capability criteria associated with this control reasonably expect the following criteria to exist: ▪ Applicable SCR-CMM Level 3 (Well Defined) capabilities are implemented and operational. ▪ Based on predictive analysis, process improvements are implemented according to “continuous improvement” practices that affect process changes. ▪ Stakeholders make time-sensitive decisions to support operational efficiency, which may include automated remediation actions via Artificial Intelligence (AI) or Machine Learning (ML) technologies.
1. Prehľad
| Názov |
Štandard |
|
Dual Authorization for Physical Access
|
Description
Mechanisms exist to enforce a "two-person rule" for physical access by requiring two authorized individuals with separate access cards, keys or PINs, to access highly-sensitive areas (e.g., safe and high-security cage).
Possible Solutions & Considerations
Micro-Small Business (<10 staff) / BLS Firm Size Classes 1-2
∙ Note: Typically not required at this size; two-person rule for safe/critical storage if applicable
Small Business (10-49 staff) / BLS Firm Size Classes 3-4
∙ Two-person rule for server room or safe access where required ∙ Dual-key or dual-code lock
Medium Business (50-249 staff) / BLS Firm Size Classes 5-6
∙ Two-person rule enforced by access control system for high-security areas ∙ Dual-authentication door readers
Large Business (250-999 staff) / BLS Firm Size Classes 7-8
∙ PACS dual-authorization (two-badge) rule for data center and high-security rooms ∙ Alarm on single-person entry
Enterprise (> 1,000 staff) / BLS Firm Size Class 9
∙ Enterprise PACS with enforced two-person rule and anti-passback ∙ Video verification of dual entry ∙ Audit reporting on two-person rule compliance
SCR-CMM
Level 0 Not Performed
Practices are non-existent, based on the inability to demonstrate an implemented and operational capability. A reasonable person would conclude the control is not being performed.
Level 1 Performed Informally
SCR-CMM Level 1 criteria definitions are not available for this control: ▪ A reasonable person would conclude this control requires a structured process. ▪ At this level of maturity, the "ad hoc" nature of performing a capability informally would indicate the intent of the control is not met due to a lack of consistency and formality.
Level 2 Planned Tracked
Physical & Environmental Security (PES) capabilities are requirements-driven, but are not standardized across the entity (e.g., local/regional level consistency). Capability criteria associated with this control reasonably expect the following criteria to exist: ▪ Policies and standards associated with PES domain capabilities are formally documented and centrally-managed by the entity. ▪ Standardized Operating Procedures (SOP) associated with PES domain capabilities are documented and maintained by process owners. ▪ IT and/or cybersecurity personnel work with business stakeholders and process owners to appropriately scope and reasonably implement cybersecurity and data protection controls associated with PES domain capabilities to address applicable statutory, regulatory and/or contractual requirements for Technology Assets, Applications, Services and/or Data (TAASD). ▪ Physical security / facilities management-related controls are primarily administrative and preventative in nature (e.g., policies, standards and procedures & guidelines). ▪ Physical security / facilities management may be a defined function (e.g., team or department) or assigned as an additional duty to existing IT and/or cybersecurity personnel. ▪ Physical security controls and technologies primarily focus on protecting High Value Assets (HVAs), including environments where sensitive/regulated data is stored, transmitted and processed.
Level 3 Well Defined
Physical & Environmental Security (PES) capabilities are standardized across the entity for applicability to People, Processes, Technologies, Data and/or Facilities (PPTDF) to ensure consistency for Technology Assets, Applications, Services and/or Data (TAASD). Capability criteria associated with this control reasonably expect the following criteria to exist: ▪ Policies and standards associated with PES domain capabilities are formally documented and centrally-managed by the entity's Governance, Risk & Compliance (GRC) team, or similar function. ▪ Standardized Operating Procedures (SOP) associated with PES domain capabilities are well-documented and kept current by process owners. ▪ A facilities management team, or similar function, is appropriately staffed and supported to implement and maintain NET domain capabilities. ▪ Technology is leveraged to enhance the efficiency and accuracy of physical and environmental security operations (e.g., facility management solution, visitor log management automation and proximity badge access). ▪ The entity's Governance, Risk & Compliance (GRC) team, or similar function, works with business stakeholders and process owners to appropriately scope and reasonably implement cybersecurity and data protection controls associated with PES domain capabilities to address Minimum Compliance Requirements (MCR) (e.g., applicable statutory, regulatory and/or contractual requirements) and Discretionary Security Requirements (DSR) (e.g., entity-required controls). ▪ An implemented and operational capability exists to enforce a "two-person rule" for physical access by requiring two authorized individuals with separate access cards, keys or PINs, to access highly-sensitive areas (e.g., safe and high-security cage).
Level 4 Quantitatively Controlled
Utilize SCR-CMM Level 3 criteria definitions: ▪ There are no defined Level 4 criteria, since it is reasonable to assume a quantitatively-controlled process is not necessary to operationalize this control. ▪ While it may be possible to develop “metrics-driven” capabilities for this control, the criteria would be organization-specific to define.
Level 5 Continuously Improving
Utilize SCR-CMM Level 3 or Level 4 (if available) criteria definitions: ▪ There are no defined Level 5 criteria, since it is reasonable to assume a continuously-improving process is not necessary to operationalize this control. ▪ Level 5 capabilities should be considered “world-class” where the control builds on Level 4 capabilities, but are continuously improving through Artificial Intelligence (AI) and/or Machine Learning (ML) technologies. ▪ While it may be possible to develop responsive capabilities for this control through the use of AI and/or ML technologies, the criteria would be organization-specific to define.
|
1.1 Odkazy
1.2 Identifikované požiadavky
1.3 Súvisiace predpisy
2. Identifikované požiadavky
Požiadavky
| Zdroj |
Požiadavka |
3. Súvisiace predpisy
Predpisy
| Zdroj |
Regulácia |
|
EULAW
|
Článok 21 Kontrola prístupu
Článok 21
Finančné subjekty v rámci svojej kontroly práv na riadenie prístupu vypracujú, zdokumentujú a vykonávajú politiku, ktorá obsahuje všetky tieto prvky:
a)
prideľovanie prístupových práv k aktívam IKT na základe zásady potreby poznať (need-to-know), zásady potreby používať (need-to-use) a zásady minimálneho privilégia (least privilege principle), a to aj v prípade vzdialeného a núdzového prístupu;
b)
segregácia povinností určených na zabránenie neoprávnenému prístupu ku kritickým údajom alebo na zabránenie prideľovaniu kombinácií prístupových práv, ktoré sa môžu použiť na obchádzanie kontrol;
c)
ustanovenie o zodpovednosti používateľa tým, že sa v čo najväčšej možnej miere obmedzí používanie generických a spoločných používateľských účtov a zabezpečí sa, aby boli používatelia vždy identifikovateľní, pokiaľ ide o činnosti, ktoré v IKT systémoch vykonávajú;
d)
ustanovenie o obmedzeniach prístupu k IKT aktívam, v ktorom sa stanovujú kontroly a nástroje na zabránenie neoprávnenému prístupu;
e)
postupy riadenia účtov na účely udeľovania, zmeny alebo odoberania prístupových práv k používateľským a generickým účtom vrátane generických správcovských účtov, vrátane ustanovení o všetkých týchto prvkoch:
i)
prideľovanie úloh a zodpovedností za udeľovanie, preskúmavanie a odoberanie prístupových práv;
ii)
prideľovanie privilegovaného, núdzového a správcovského prístupu na základe potreby používať (need-to-use) alebo na ad hoc základe pre všetky IKT systémy;
iii)
odobratie prístupových práv bez zbytočného odkladu po skončení pracovného pomeru, alebo ak prístup už nie je potrebný;
iv)
aktualizácia prístupových práv, ak sú potrebné zmeny, a to aspoň raz ročne v prípade všetkých IKT systémov iných ako IKT systémy podporujúce kritické alebo dôležité funkcie a aspoň každých 6 mesiacov v prípade IKT systémov podporujúcich kritické alebo dôležité funkcie;
f)
metódy autentifikácie vrátane všetkých týchto prvkov:
i)
používanie metód autentifikácie zodpovedajúcich klasifikácii stanovenej v súlade s článkom 8 ods. 1 nariadenia (EÚ) 2022/2554 a celkovému rizikovému profilu IKT aktív a s prihliadnutím na popredné postupy;
ii)
používanie silných metód autentifikácie v súlade s poprednými postupmi a technikami v prípade vzdialeného prístupu do siete finančného subjektu, privilegovaného prístupu, prístupu k IKT aktívam podporujúcim kritické alebo dôležité funkcie alebo IKT aktívam, ktoré sú verejne prístupné;
g)
opatrenia na kontrolu fyzického prístupu vrátane týchto prvkov:
i)
identifikácia a vedenie záznamov o fyzických osobách, ktoré majú povolenie na prístup do priestorov, do dátových centier a citlivých určených oblastí identifikovaných finančným subjektom, v ktorých majú sídlo IKT a informačné aktíva;
ii)
udeľovanie fyzických prístupových práv ku kritickým IKT aktívam len oprávneným osobám v súlade so zásadou potreba poznať (need-to-know) a zásadou minimálneho privilégia a na ad hoc základe;
iii)
monitorovanie fyzického prístupu do priestorov, do dátových centier a citlivých určených oblastí identifikovaných finančným subjektom, v ktorých majú sídlo IKT a informačné aktíva alebo oboje;
iv)
preskúmanie fyzických prístupových práv na zabezpečenie urýchleného odobratia nepotrebných prístupových práv.
Na účely písmena e) bodu i) finančné subjekty stanovia obdobie uchovávania, pričom zohľadnia obchodné ciele a ciele v oblasti informačnej bezpečnosti, dôvody zaznamenania udalosti do záznamových protokolov a výsledky posudzovania IKT rizika.
Na účely písmena e) bodu ii) finančné subjekty podľa možnosti používajú na plnenie administratívnych úloh týkajúcich sa IKT systémov osobitné účty. Ak je to uskutočniteľné a vhodné, finančné subjekty zavedú na riadenie privilegovaného prístupu automatizované riešenia.
Na účely písmena g) bodu i) zodpovedá identifikácia a vedenie záznamov významu priestorov, dátových centier, citlivých určených oblastí a kritickosti operácií alebo IKT systémov, ktoré sa v nich nachádzajú.
Na účely písmena g) bodu iii) zodpovedá monitorovanie klasifikácii stanovenej v súlade s článkom 8 ods. 1 nariadenia (EÚ) 2022/2554 a kritickosti oblasti, do ktorej sa pristupuje.
|
Prepojené úlohy
- Secure Controls Framework -
EN: GRCA includes the Secure Controls Framework® (SCF) content, © Secure Controls Framework Council, LLC, used under the Creative Commons Attribution-NoDerivatives 4.0 International Public License. SCF control numbers, names, descriptions and mappings appear exactly as published by the SCF Council – https://securecontrolsframework.com. GRCA may group or reorder SCF content for display, which does not change SCF content; the mappings are shown as links to the frameworks they name. Learn more at https://securecontrolsframework.com.
DE: GRCA enthält Inhalte des Secure Controls Framework® (SCF), © Secure Controls Framework Council, LLC, genutzt unter der Creative Commons Attribution-NoDerivatives 4.0 International Public License. Nummern, Namen, Beschreibungen und Zuordnungen der SCF-Controls erscheinen genau so, wie der SCF Council sie veröffentlicht – https://securecontrolsframework.com. GRCA gruppiert oder sortiert SCF-Inhalte für die Anzeige, ohne sie zu verändern; die Zuordnungen erscheinen als Verknüpfungen zu den genannten Regelwerken. Mehr unter https://securecontrolsframework.com.
|