+ANNESS II
|
ANNESS II
ANNESS II
Il-limiti tal-emissjonijiet tal-egżost imsemmija fl-Artikolu 18(2)
Tabella II-1: Il-limiti tal-emissjonijiet tal-Istadju V għall-kategorija ta' magni NRE definita fil-punt (1) tal-Artikolu 4(1)
|
Stadju tal-emissjonijiet
|
Subkategorija tal-magna
|
Medda tal-potenza
|
Tip ta' ignixin
|
CO
|
HC
|
NOx
|
Massa ta' PM
|
PN
|
A
|
|
|
|
kW
|
|
g/kWh
|
g/kWh
|
g/kWh
|
g/kWh
|
#/kWh
|
|
|
Stadju V
|
NRE-v-1
NRE-c-1
|
0 < P < 8
|
CI
|
8,00
|
(HC + NOx ≤ 7,50)
|
0,40 (1)
|
—
|
1,10
|
|
Stadju V
|
NRE-v-2
NRE-c-2
|
8 ≤ P < 19
|
CI
|
6,60
|
(HC + NOx ≤ 7,50)
|
0,40
|
—
|
1,10
|
|
Stadju V
|
NRE-v-3
NRE-c-3
|
19 ≤ P < 37
|
CI
|
5,00
|
(HC + NOx ≤ 4,70)
|
0,015
|
1 × 1012
|
1,10
|
|
Stadju V
|
NRE-v-4
NRE-c-4
|
37 ≤ P < 56
|
CI
|
5,00
|
(HC + NOx ≤ 4,70)
|
0,015
|
1 × 1012
|
1,10
|
|
Stadju V
|
NRE-v-5
NRE-c-5
|
56 ≤ P < 130
|
kollha
|
5,00
|
0,19
|
0,40
|
0,015
|
1 × 1012
|
1,10
|
|
Stadju V
|
NRE-v-6
NRE-c-6
|
130 ≤ P ≤ 560
|
kollha
|
3,50
|
0,19
|
0,40
|
0,015
|
1 × 1012
|
1,10
|
|
Stadju V
|
NRE-v-7
NRE-c-7
|
P > 560
|
kollha
|
3,50
|
0,19
|
3,50
|
0,045
|
—
|
6,00
|
(1)
0,60 għall-magni ta' injezzjoni diretta mkessħa bl-arja li jistartjaw bl-idejn
|
Tabella II-2: Il-limiti tal-emissjonijiet tal-Istadju V għall-kategorija ta' magni NRG definita fil-punt (2) tal-Artikolu 4(1)
|
Stadju tal-emissjonijiet
|
Subkategorija tal-magna
|
Medda tal-potenza
|
Tip ta' ignixin
|
CO
|
HC
|
NOx
|
Massa ta' PM
|
PN
|
A
|
|
|
|
kW
|
|
g/kWh
|
g/kWh
|
g/kWh
|
g/kWh
|
#/kWh
|
|
|
Stadju V
|
NRG-v-1
NRG-c-1
|
P > 560
|
kollha
|
3,50
|
0,19
|
0,67
|
0,035
|
—
|
6,00
|
Tabella II-3: Il-limiti tal-emissjonijiet tal-Istadju V għall-kategorija ta' magni NRSh definita fil-punt (3) tal-Artikolu 4(1)
|
Stadju tal-emissjonijiet
|
Subkategorija tal-magna
|
Medda tal-potenza
|
Tip ta' ignixin
|
CO
|
HC + NOx
|
|
|
|
kW
|
|
g/kWh
|
g/kWh
|
|
Stadju V
|
NRSh-v-1a
|
0 < P < 19
|
SI
|
805
|
50
|
|
Stadju V
|
NRSh-v-1b
|
603
|
72
|
Tabella II-4: Il-limiti tal-emissjonijiet tal-Istadju V għall-kategorija ta' magni NRS definita fil-punt (4) tal-Artikolu 4(1)
|
Stadju tal-emissjonijiet
|
Subkategorija tal-magna
|
Medda tal-potenza
|
Tip ta' ignixin
|
CO
|
HC + NOx
|
|
|
|
kW
|
|
g/kWh
|
g/kWh
|
|
Stadju V
|
NRS-vr-1a
NRS-vi-1a
|
0 < P < 19
|
SI
|
610
|
10
|
|
Stadju V
|
NRS-vr-1b
NRS-vi-1b
|
610
|
8
|
|
Stadju V
|
NRS-v-2a
|
19 ≤ P ≤ 30
|
610
|
8
|
|
Stadju V
|
NRS-v-2b
NRS-v-3
|
19 ≤ P < 56
|
4,40 (*1)
|
2,70 (*1)
|
(*1)
B'mod fakultattiv, bħala alternattiva, kwalunkwe kombinazzjoni ta' valuri li tissodisfa l-ekwazzjoni (HC + NOX) × CO0,784 ≤ 8,57 kif ukoll il-kondizzjonijiet li ġejjin: CO ≤ 20,6 g/kWh u (HC + NOX) ≤ 2,7 g/kWh.
|
Tabella II-5: Il-limiti tal-emissjonijiet tal-Istadju V għall-kategorija ta' magni IWP definita fil-punt (5) tal-Artikolu 4(1)
|
Stadju tal-emissjonijiet
|
Subkategorija tal-magna
|
Medda tal-potenza
|
Tip ta' ignixin
|
CO
|
HC
|
NOx
|
Massa ta' PM
|
PN
|
A
|
|
|
|
kW
|
|
g/kWh
|
g/kWh
|
g/kWh
|
g/kWh
|
#/kWh
|
|
|
Stadju V
|
IWP-v-1
IWP-c-1
|
19 ≤ P < 75
|
kollha
|
5,00
|
(HC + NOx ≤ 4,70)
|
0,30
|
—
|
6,00
|
|
Stadju V
|
IWP-v-2
IWP-c-2
|
75 ≤ P < 130
|
kollha
|
5,00
|
(HC + NOx ≤ 5,40)
|
0,14
|
—
|
6,00
|
|
Stadju V
|
IWP-v-3
IWP-c-3
|
130 ≤ P < 300
|
kollha
|
3,50
|
1,00
|
2,10
|
0,10
|
—
|
6,00
|
|
Stadju V
|
IWP-v-4
IWP-c-4
|
P ≥ 300
|
kollha
|
3,50
|
0,19
|
1,80
|
0,015
|
1 × 1012
|
6,00
|
Tabella II-6: Il-limiti tal-emissjonijiet tal-Istadju V għall-kategorija ta' magni IWA definita fil-punt (6) tal-Artikolu 4(1)
|
Stadju tal-emissjonijiet
|
Subkategorija tal-magna
|
Medda tal-potenza
|
Tip ta' ignixin
|
CO
|
HC
|
NOx
|
Massa ta' PM
|
PN
|
A
|
|
|
|
kW
|
|
g/kWh
|
g/kWh
|
g/kWh
|
g/kWh
|
#/kWh
|
|
|
Stadju V
|
IWA-v-1
IWA-c-1
|
19 ≤ P < 75
|
kollha
|
5,00
|
(HC + NOx ≤ 4,70)
|
0,30
|
—
|
6,00
|
|
Stadju V
|
IWA-v-2
IWA-c-2
|
75 ≤ P < 130
|
kollha
|
5,00
|
(HC + NOx ≤ 5,40)
|
0,14
|
—
|
6,00
|
|
Stadju V
|
IWA-v-3
IWA-c-3
|
130 ≤ P < 300
|
kollha
|
3,50
|
1,00
|
2,10
|
0,10
|
—
|
6,00
|
|
Stadju V
|
IWA-v-4
IWA-c-4
|
P ≥ 300
|
kollha
|
3,50
|
0,19
|
1,80
|
0,015
|
1 × 1012
|
6,00
|
Tabella II-7: Il-limiti tal-emissjonijiet tal-Istadju V għall-kategorija ta' magni RLL definita fil-punt (7) tal-Artikolu 4(1)
|
Stadju tal-emissjonijiet
|
Subkategorija tal-magna
|
Medda tal-potenza
|
Tip ta' ignixin
|
CO
|
HC
|
NOx
|
Massa ta' PM
|
PN
|
A
|
|
|
|
kW
|
|
g/kWh
|
g/kWh
|
g/kWh
|
g/kWh
|
#/kWh
|
|
|
Stadju V
|
RLL-c-1
RLL-v-1
|
P > 0
|
kollha
|
3,50
|
(HC + NOx ≤ 4,00)
|
0,025
|
—
|
6,00
|
Tabella II-8: Il-limiti tal-emissjonijiet tal-Istadju V għall-kategorija ta' magni RLR definita fil-punt (8) tal-Artikolu 4(1)
|
Stadju tal-emissjonijiet
|
Subkategorija tal-magna
|
Medda tal-potenza
|
Tip ta' ignixin tal-magna
|
CO
|
HC
|
NOx
|
Massa ta' PM
|
PN
|
A
|
|
|
|
kW
|
|
g/kWh
|
g/kWh
|
g/kWh
|
g/kWh
|
#/kWh
|
|
|
Stadju V
|
RLR-c-1
RLR-v-1
|
P > 0
|
kollha
|
3,50
|
0,19
|
2,00
|
0,015
|
1 × 1012
|
6,00
|
Tabella II-9: Il-limiti tal-emissjonijiet tal-Istadju V għall-kategorija ta' magni SMB definita fil-punt (9) tal-Artikolu 4(1)
|
Stadju tal-emissjonijiet
|
Subkategorija tal-magna
|
Medda tal-potenza
|
Tip ta' ignixin
|
CO
|
NOx
|
HC
|
|
|
|
kW
|
|
g/kWh
|
g/kWh
|
g/kWh
|
|
Stadju V
|
SMB-v-1
|
P > 0
|
SI
|
275
|
—
|
75
|
Tabella II-10: Il-limiti tal-emissjonijiet tal-Istadju V għall-kategorija ta' magni ATS definita fil-punt (10) tal-Artikolu 4(1)
|
Stadju tal-emissjonijiet
|
Subkategorija tal-magna
|
Medda tal-potenza
|
Tip ta' ignixin
|
CO
|
HC + NOx
|
|
|
|
kW
|
|
g/kWh
|
g/kWh
|
|
Stadju V
|
ATS-v-1
|
P > 0
|
SI
|
400
|
8
|
Dispożizzjonijiet speċifiċi dwar il-limiti totali tal-idrokarburi (HC) għall-magni li jaħdmu bi fjuwils kompletament jew parzjalment gassużi
1. Għas-subkategoriji fejn huwa definit fattur A, il-limitu tal-HC għall-magni li jaħdmu bi fjuwils kompletament jew parzjalment gassużi indikati fit-Tabelli II-1 sa II-10 jiġi sostitwit b'limitu kkalkolat bl-użu tal-formula li ġejja:
HC = 0,19 + (1,5 × A × GER) fejn GER huwa l-proporzjon enerġetiku tal-gass medju fuq iċ-ċiklu tat-test xieraq. Meta japplikaw kemm iċ-ċiklu tat-test f'qagħda statika kif ukoll iċ-ċiklu tat-test transitorju, il-GER għandu jiġi determinat miċ-ċiklu tat-test transitorju bi startjar sħun. Meta japplika aktar minn ċiklu wieħed tat-test f'qagħda statika, il-proporzjon GER għandu jiġi determinat għal kull ċiklu individwalment. Jekk il-limitu kkalkolat għall-HC jaqbeż il-valur ta' 0,19 + A, il-limitu għall-HC għandu jiġi stabbilit għal 0,19 + A.
Grafika 1. Dijagramma li turi l-limitu tal-emissjonijiet ta' HC bħala funzjoni tal-GER medju
2. Għas-subkategoriji b'limitu kkombinat ta' HC u NOx, il-valur tal-limitu kkombinat għall-HC u l-NOx għandu jitnaqqas b'0,19 g/kWh u japplika biss għall-NOx.
3. Il-formula ma tapplikax għall-magni li jaħdmu bi fjuwils mhux gassużi.
1. Ħarsa ġenerali
| Titlu |
Regolamentazzjoni |
,
1.1 Referenzi
1.2 Rekwiżiti identifikati
1.3 Standards relatati
2. Rekwiżiti identifikati